loading spinner
Chauvin C.A 8336 Qualistar+
  • Chauvin C.A 8336 Qualistar+
  • Chauvin C.A 8336 Qualistar+
  • Chauvin C.A 8336 Qualistar+

Chauvin C.A 8336 Qualistar+

Chauvin Arnoux authorised distributor and calibration house.

The Chauvin C.A. 8336 (Qualistar+) is a three-phase network analyzer with colour graphic display and built-in rechargeable battery.

Quantity
  HTTPS Secure

Our pages are encrypted and protected from cyber-attack.

  Compliant

Payment Card Industry Data Security Standard (PCI DSS) Compliant.

  Protected

TLS (SSL) - all data/information is secure from interception.

NB: This unit does not include current clamps.

Designed for inspection and maintenance teams in industrial or administrative buildings, the Qualistar can provide a snapshot of the main electrical network quality characteristics. Easy to handle and precise, these instruments also offer a large number of calculated values and several processing functions.

Easy to handle and particularly compact, this instrument also offers a large number of calculated values and several processing functions. The C.A 8336 is equipped with 4 voltage measurement channels and 4 current measurement channels. The Chauvin Arnoux C.A 8336 captures and records all the parameters, transients, alarms and waveforms simultaneously.

The measurement uncertainty of the C.A 8336 is better than 1% (not counting the uncertainties due to the current sensors). The device is also very flexible, with a choice of sensors allowing measurements ranging from a few milliamperes (MN93A) to several kiloamperes (AmpFLEX™).

The Qualistar is particularly simple to set up. Connection  of the instrument is easy thanks to the colour-coded terminals and cables (coloured ring at each end of the cable). When it is switched on, the Qualistar automatically recognises all the current sensors connected, whatever their type.

The C.A8336 analyser's functions make it the ideal instrument for preventive or corrective maintenance. It can also be used to perform a complete energy survey of an installation.

MEASUREMENT FUNCTIONS

Real-time display of wave forms (4 voltages and 4 currents).
Half-period RMS measurements of voltages and currents.
Intuitive use.
Automatic recognition of the different types of current sensors.
Measurement on any type of installation: three-phase, Aron, etc.
Integration of all the DC components.
Measurement, calculation and display of harmonics up to the 50th order.
Display of phasor diagram.
Measurement of P, Q, S and D power values (total and per phase).
Energy measurement (total and per phase).
Calculation of the K Factor & FHL.
Calculation of distorting voltages and currents.
Calculation of the cos φ displacement power factor (DPF) and the power factor (PF).
Inrush over up to 10 minutes.
Capture of hundreds of transients lasting several tens of μs.
Calculation of Pst & Plt flicker values.
Unbalance calculation (current and voltage).
Monitoring of the electrical network with setting of alarms.
IEC 61000-4-30 Class B.
Back-up and recording of screenshots (image and data).
Recording and export on PC.
Software for data recovery and real-time communication with a PC.

Chauvin C.A 8336 Specifications:

  • Number of channels: 4U / 4I.
  • Number of inputs: 5V / 4I.
  • Voltage (TRMS AC+DC): 2 V to 1,000 V.
  • Voltage ratio: up to 500 kV.
  • Current (TRMS AC+DC): AmpFlex® or MA193 clamps - 100 mA to 10,000 Aac.
  • Frequency: 40 Hz to 69 Hz.
  • Power values: W, VA, var, VAD, PF, DPF, cos φ, tan φ.
  • Energy values: Wh, varh, VAh, VADh.
  • Harmonics: THD - yes, orders 0 to 50, phase, plus Expert mode.
  • Transients: 210.
  • Flicker: Pst + Plt - yes.
  • Inrush mode: yes > 10 minutes.
  • Recording: 2 weeks to several years.
  • Alarms: 10,000 of 40 different types.
  • Peak: yes
  • Vectorial representation: automatic.
  • USB communication.
  • IEC 61000-4-30 Class B.
  • Display: Colour 1/4 VGA TFT screen, 320 x 240, diagonal 148mm.
  • Capture of Screens and Curves: 12.
  • Power Supply: 9.6V NiMH rechargeable battery or external mains charger.
  • Battery life: up to 13 hours.
  • Dimensions: 240 x 180 x 55 mm.
  • Weight: 1.9kg.
  • Chauvin C.A 8336 Qualistar+ Warranty: 3 years.

Includes: Chauvin Arnoux CA8336 Qualistar+ Power Quality Analyser, 5 x 4mm Banana Leads (3m Length), 5 x Crocodile Clips, Set of 12x Colour Inserts, Scratch-Proof Screen Protection Film, USB Cable, Mains Power Cable, Mains Power Pack, Safety Datasheet, Multi-Language Operating Manual CD, PC Data Retrieval Software CD (Power Analyser Transfer).

P01160591

Download

Chauvin Qualistar Datasheet

PDF Specifications of the CHauvin Arnoux CA 8331, CA 8333, CA 8336 & CA 8346.

Download (5.29M)

16 other products in the same category:

arrow_upward