Chauvin PEL104 Power Logger
Includes: 1x carrying bag, 4x voltage cables, 4x crocodile clips, 1 set of rings/inserts, 1 x 600V mains adapter, 1x SD card, 1x SD - USB adapter, 1 USB cable, PC PEL TRANSFER software & user’s manual to download from the website, 1 quick start guide.
Our pages are encrypted and protected from cyber-attack.
Payment Card Industry Data Security Standard (PCI DSS) Compliant.
TLS (SSL) - all data/information is secure from interception.
The Chauvin Arnoux PEL104 power logger measures and records all the useful data for energy consumption diagnostics. The PEL104 can be used without cutting off the mains power supply.
Portable, rugged and compact, its magnetised casing makes it easy to set up, including in an electrical cabinet. The PEL104 is a logger equipped with 3 voltage channels and 3 current channels. No more battery problems, as the logger self-powers directly via the phase by means of the accessory included.
The backlit LCD screen equipped with a triple digital display is particularly easy to read. The PEL 104 is also equipped with an SD card capable of storing several years' data, an ideal function for measurement campaigns.
FEATURES
Compact magnetised casing.
Communication via Wifi, 3G-UMTS/GPRS, LAN (Ethernet), Bluetooth and USB.
ANDROID application.
Self-powered via its voltage inputs up to 600 V.
Continuous recording with an interval of 200 ms between measurements.
Measurements as per the IEEE 1459 standard.
Measurements of the fundamental active power.
4 voltage inputs and 3 current inputs.
5 measurements per second, simultaneously on each phase.
Active, apparent and reactive power values.
Phase: cos phi, tan PHI, PF.
Harmonics/THD.
Sending of periodic reports by email.
Display | With quadruple digital display. | ||
Installation types | Single-phase, split-phase, three-phase with or without neutral and many other specific configurations. | ||
Number of channels | 4 voltage inputs, 4 current inputs. | ||
Measurements | |||
Network frequency | 50 Hz, 60 Hz & 400 Hz. | ||
Voltage (measurement ranges) | 10.00 - 1,000 Vac/dc. | ||
Current (depending on sensor)
(measurement ranges) |
5 mA ac to 10 kA ac / 50 mA dc to 1.4 kA dc | ||
Calculated Measurements | |||
Ratio | Up to 650,000 V / up to 25,000 A. | ||
Power | 10 W to 10 GW / 10 var to 10 Gvar / 10 VA to 10 GVA. | ||
Energy | Up to 4EWh / 4 EVAh / 4 Evarh. | ||
Phase | cos φ, tan Φ, PF. | ||
Harmonics | THD. | ||
Complementary Functions | |||
Phase order | Yes. | ||
Min/max | Yes. | ||
Mounting | Hook (optional). | ||
Recording | |||
Sampling / Acquisition rate / Aggregation | 5 measurements/s - from 1 min to 60 min. | ||
Memory | SD card 2 GB (SD-HC up to 32 GB). | ||
Communication | Ethernet , Bluetooth, USB, Wifi and GPRS. | ||
Power supply | Power supply via the phase 1,000 V AC/DC. |
||
Safety | IEC 61010 1000 V CAT IV. | ||
Casing |
IP67. | ||
Mechanical | |||
Dimensions | 245 x 270 180 mm without sensor. | ||
Weight | <3400 g. | ||
Chauvin PEL103 warranty | 2 years. |