Fluke 1775 Three-Phase Power Quality Analyser
  • Fluke 1775 Three-Phase Power Quality Analyser
  • Fluke 1775 Three-Phase Power Quality Analyser
  • Fluke 1775 Three-Phase Power Quality Analyser
  • Fluke 1775 Three-Phase Power Quality Analyser

Fluke 1775 Three-Phase Power Quality Analyser

Fluke authorised distributor and calibration house.

Includes: Fluke-1775, I17XX-FLEX1500 24 iFlex 1500A 24 In (2.0M) current probes (set of four), Fluke-17XX flat cable voltage test lead 3-phase+N, AC285 black alligator clips (set of four), AC285 green alligator clip, Black 1M USB-C cable, Line cords, FLK-17XX 0.18M test lead set, Green test lead, MP1-3R/1B Magnet Probe set, FLUKE-174X-HANGER magnetic hanging kit, Fluke-177X-4204, WI-FI/BLE module, Cable marker set (for voltage and current), Fluke-174X-MA-C8 wall outlet adapter, Black soft case.

Fluke 1770 Series Options
Quantity
  HTTPS Secure

Our pages are encrypted and protected from cyber-attack.

  Compliant

Payment Card Industry Data Security Standard (PCI DSS) Compliant.

  Protected

TLS (SSL) - all data/information is secure from interception.

The Fluke 1775 3-Phase Power Quality Analyser is a rugged, portable device for troubleshooting power quality. The compact size and power supply from the measurement line makes it a versatile tool for live measurements and long-term logging.

Fluke 1770 Series Three-Phase Power Quality Analysers eliminate the complexities of power quality logging, troubleshooting, and analysis. Engineered to be the faster, easier way to perform power quality studies, the 1770 Series offers automatic measurements, a straightforward user interface and setup, best-in-class specifications, and a simplified reporting platform. The instrument can also be powered directly from the measurement circuit, eliminating the need to find a power outlet or use a lengthy extension cord.

The Fluke 1770 Series are 2-in-1 devices that combine the trouble-shooting functionality of a power quality meter with the robust analysis and logging capabilities of a standalone power quality analyser - in a single, easy-to-use, handheld device.

WiFi/BLE Module (Not supplied with the Basic models).

The WiFi/BLE module enables the wireless connectivity. Wireless connectivity is the preferred data transfer method when the Product is installed in hazardous environments, such as, cabinets.

The WiFi/BLE module enables these features:

Wireless data transfer to Energy Analyze Plus PC software.
Time synchronization with NTP.
Remote control via Virtual Network Computing (VNC). See Remote Display for more information about VNC.

A WiFi/BLE Module is included and pre-installed. If necessary, the module is removable or you can install a module to upgrade a basic model.

FEATURES

3-Phase voltage measurement inputs with reference to N and N-to-PE measurement.
4 current measurement inputs for 3-phases and Neutral.
2 auxiliary measurement inputs for measurements of non-electrical units: temperature, humidity, light intensity.
Power supply 100 V ac to 600 V ac and 100 V dc to 660 V dc with safety sockets for powering from measurement line.
7-inch display with capacitive touch.
GPS time synchronisation.
USB interfaces: Type A for Flash drives and USB-C for wired connection to PC and power supply.
Slot for Wi-Fi/BLE module.
Slot for LTE-4G module.
Ethernet 1000Base-T.
User-accessible micro SD slot for flash memory expansion.

APPLICATIONS 1773 1775 1777
Energy surveys and load testing
Harmonic surveys
Nuisance circuit breaker tripping
Power utility power quality surveys
Discovery of equipment failures caused by transients

From traditional industrial systems to renewable energy systems to electric vehicles....

Fluke 1770 Series Included Accessories
Model
ITEM 1773 1773/B 1775 1775/B 1777 1777/B
4x Fluke-17XX IFLEX 1500 A 24 IN, 2.0 M - - -
Voltage Test Lead, 3-phase + N
4x AC285 (Black)
1x AC285 (Green)
1x Black 1M USB-C cable
1x Mains
1x FLK-17XX 0.18M test lead set.
1x Green test lead
3x Red Magnet Probes, 1 Black - - - -
Hanger kit - - - -
WiFi/BLE Module - - - -
Cable Marker Set (V & A)
Wall Outlet Adapter
Statement Of calibration Practices
Black Soft Case
Fluke 1777 Hard Case - -

Fluke 1770 Series Three-Phase Power Quality Analyser Specifications
Voltage inputs
Number of inputs 4 inputs, 3 phases and neutral referenced to PE (5 connectors).
Measurement category 1000 V CAT III / 600 V CAT IV
Maximum input voltage 1000 V rms / 1000 V dc (1700 Vpk)
Nominal voltage range Wye and single phase: variable (50 V – 1000 V)
Delta: Variable (100 V – 1000 V)
IEC 61000-4-30 Class A compliance for the nominal voltages (Vdin) 100 V – 690 V
Input impedance 10 MΩ between P-P and P-N, 5 MΩ between P-PE and N-PE
Bandwidth DC to 30 kHz for PQ measurements, excluding transients
Resolution 24-bit synchronous sampling
Sampling frequency 80 kS/s at 50/60 Hz
Scaling 1:1, variable for use of potential transformers
Voltage transients
Measurement range ±8 kV
Sampling rate 1775: 1 MS/s
1777: 1 MS/s, 20 MS/s
Bandwidth DC to 1 MHz
Trigger Adjustable trigger level. Triggers on high-frequency components > 1.5 kHz
Resolution 14-bit synchronous sampling
Current inputs
Number of inputs 4 inputs 3 phases and Neutral, range selected automatically to attached sensor
Range AC 1 A to 1500 A with i17XX-FLEX1500 12
1 A to 1500 A with i17XX-FLEX1500 24
3 A to 3000 A with i17XX-FLEX3000 24
6 A to 6000 A with i17XX-FLEX6000 36
40 mA to 40 A with clamp i40s-EL
4 A to 400 A with clamp i400s-EL
DC 20 A to 2000 A with 80i-2010-EL clamp
Bandwidth DC to 30 kHz
Resolution 24-bit synchronous sampling
Sampling frequency 80 kS/s at 50/60 Hz
Scaling 1:1, variable
Input voltage Clamp: 50 mV / 500 mV rms; CF 2.8
Rogowski Coil: 15 mV / 150 mV rms at 50 Hz, 18 mV / 180 mV rms at 60 Hz; CF 4
all at nominal probe range
Input impedance 11 kΩ
Aux inputs
Wired connection with 17XX-AUX adapter.
Number of inputs 2
Input range Direct: 0 V dc to ± 10 V dc
0 V to 1000 V dc.
Input impedance Direct: 2.92 MΩ.
Scale factor Format: mx + b (gain and offset) user configurable.
Displayed units User configurable (up to 8 characters, for example °C, psi, or m/s).
Data acquisition voltage and current
Input mains frequency DC, 50/60 Hz  15 % (42.5 Hz … 57.5 Hz, 51 Hz … 69 Hz).
Topologies 1-φ, 1-φ IT, Split phase, 3-φ delta, 3-φ wye IT, 3-φ Aron/Blondel (2 element delta), 3-φ delta open leg, 3-φ high leg delta.
Data storage Fluke 1773/1775: 8 GB internal (expandable with microSD card)
Fluke 1777: 32 GB microSD card (installed).
Memory size Typical 10 logging sessions of 8 weeks with 1-minute intervals and 100 events.
The number of possible logging sessions and logging period depends on user requirements.
Real time accuracy Internal: 3 ppm (0.26 s per day, 8 s per month)
NTP (internet time): Depending on internet latency, typical < 0.1 s absolute to UTC
GPS: < 1 ms absolute to UTC.
Trend interval
Measured parameter See operator manual.
Trend interval User selectable: 1 sec, 3 sec, 5 sec, 10 sec, 30 sec, 1 min, 5 min, 10 min, 15 min, 30 min.
Averaging interval min/max values Voltage, Current: ½ cycle RMS (20 ms at 50 Hz, 16.7 ms at 60 Hz)
Aux, Power: 200 ms.
Total harmonic distortion THD for voltage and current is calculated on 50 harmonics.
Power quality measurements
Measured parameter See operator manual.
Harmonics h0 … h50
% fund and RMS for voltage, current and power
Phase angles for voltage and current up to h11.
Interharmonics ih0… ih50
% fund and RMS for voltage and current.
Supraharmonics 2–9 kHz with 200 Hz bins
9–30 khz with 2 kHz bins
RMS for voltage and current.
Harmonics measurement method Grouped, sub-grouped and single harmonic bins according to IEC 61000-4-7.
Method selected automatically based on configured PQ standard or user configurable.
Total harmonic distortion Calculated on up to 50 harmonics (depends on selected PQ standard).
Mains signaling 2 frequencies in the range from 110 Hz to 3000 Hz.
Events Voltage Dip, swell, interruption, rapid voltage change, mains signaling, waveshape deviation, transients.
Current Inrush current.
Triggered recordings Half cycle RMS of voltage and current for 10 s
Waveform of voltage and current for 10/12 cycles
Mains signaling: 200 ms RMS of mains signaling voltage up to 120 s
Transients: Waveform of voltage
(Fluke 1777: 1 MS/s or 20 MS/s, 500,000 pts, Fluke 1775: 1 MS/s, 25,000 pts).
Standard compliance
Power IEEE 1459
Harmonics IEC 61000-4-7: Class 1
IEEE 519 (short time and very short time harmonics).
Flicker IEC 61000-4-15 Class F1.
Power quality IEC 61000-4-30 Class A, IEC 62586 PQI-A-PI.
Power quality compliance EN 50160 + GOST + NEQUAL + NETCODE + FOL.
Interfaces
Ethernet 1 Gbit/s 1000BASE-T.
USB type A USB 2.0 high speed for USB flash drives to transfer measurement data, firmware updates and license installation. Max. supply current: 500 mA
USB-C USB 2.0 high speed for data download to PC and calibration (requires USB type A to USB-C or USB-C to USB-C cable)
Auxiliary power supply for the Analyzer (requires USB C power adapter PD 2.0 or higher with 9 V 1.8 A support)
USB 3.0 super-speed for USB-C flash drives to transfer measurement data, firmware updates and license installation. Max. supply current: 900 mA.
WiFi/BLE module1 802.11 ac 2.4 GHz / 5 GHz, support for concurrent access point and client mode
Bluetooth 5.0/BLE
Antenna: Internal and external2.
LTE/4G module3 LTE-A Cat 12
Worldwide LTE-A and UMTS/HSPA+ coverage
Antenna: External2.
GPS MCX connector to attach a GNSS antenna for GPS/GLONASS2.
1 Not in 177X/BASIC versions
2 Requires 5m extension cable, Fluke p/n 5263915
3 Availability and supported providers vary by country. Check with your local Fluke representative.
General Specifications
Key features
Warranty Analyser: 2 years (battery not included)
Accessories: 1 year (including battery).
Calibration cycle 2 years.
Size (L X W X HD) 28.0 cm x 19.0 cm x 6.2 cm (11.0 in x 7.5 in x 2.4 in).
Weight 2.1 kg (4.6 lb).
Anti-theft protection Slot to support Kensington lock.
Environmental specifications
Operating temperature range -10 °C to 50 °C.
Storage temperature range -20 °C to 60 °C.
Operating humidity IEC 60721-3-3: 3K5, modified:
-10 °C to 30 °C: ≤95 %, no condensation or ice
35 °C: 70 %
40 °C: 55 %
50 °C: 35 %
IP Rating IEC 60529: IP50.
Vibration IEC 60721-3-3 / 3M2.
Power supply
Voltage range 100 V – 600 V -15 % / +10 % (85 V … 660 V).
Power consumption Max. 40 VA.
Mains frequency 50/60 Hz (42.5 Hz … 69 Hz).
UPS Li-Ion battery BP1770 with extended temperature range, customer replaceable
On-battery runtime: 1.5 hours.
Safety
General IEC 61010-1: Pollution Degree 2.
Power supply Overvoltage Category IV 600 V
With Mains Adapter MA-C8: Overvoltage Category II 300 V.
Measurement IEC 61010-2-030: CAT IV 600 V, CAT III 1000 V.
Altitudes 2000 m to 4000 m Derate to:
Power Supply: Category IV 300 V
With MA-C8 Adapter: Category II 150 V
Measurement: CAT IV 300 V, CAT III 600 V, CAT II 1000 V.
5117278

Download

Fluke 1770 Series Datasheet

PDF Specifications of the Fluke 1770 Series Three-Phase Power Quality Analysers.

Download (1.45M)
COMPONENT
DESCRIPTION PART No.
Antenna Cable Antenna Cable, 5M, 50OHMS, 6GHZ. 5263915
WiFi/BLE WI-FI/BLE Module, Fluke-177X. 5280639
Battery 177X LI-ION Battery, BP177X 3.56V, 4000MAH. 5272862
Cable Marker Set Fluke-17XX Cable Marker Set, 05MM, (colour). 5312406
Hard Case C1777, Hard Case. 5307460
Soft Case C177X Soft Case, Fluke-177X & NORMA 6000, Black. 5307472
iFlex Fluke-17XX iFlexI 1500A 24 IN. 5171005