Includes: Laser sensor, Laser prism, Chain-type mounting bracket with 150 mm support posts (2x), 300 mm support post (4x), Micro fiber cleaning cloth, Sensor cable, PC cable, USB drive, USB drive cable, Tape measure, Wireless Bluetooth® module, Power adapter, Instruction kit and carrying case.
Our pages are encrypted and protected from cyber-attack.
Payment Card Industry Data Security Standard (PCI DSS) Compliant.
TLS (SSL) - all data/information is secure from interception.
The Fluke 830 is a laser alignment device used in industrial environments for shaft alignment only. This user-friendly tool, which is used to determine the alignment condition of rotating machinery, features an alphanumeric keyboard with strategically placed navigation keys that handle all data entry functions.
The 830 possesses a high resolution colour backlit TFT screen, file storage capacity of up to 200 measurement files, and an alignment condition LED that gives the instant alignment status of machines. The Fluke 830 uses rechargeable batteries as well as wireless communication between the 830 and its sensor.
The Fluke 830 uses a patented single laser precision alignment system that provides accurate and repeatable measurement results so you can be assured you're addressing misalignment problems properly.
FEATURES
Single laser measurement technology means reduced errors from backlash.
Intuitive guided user interface quickly and easily complete machine alignments.
Compass measurement mode enables flexible, reliable and repeatable measurements using an activated electronic inclinometer.
Dynamic machine tolerance check provides continuous evaluation of alignment adjustments.
Unique extend mode handles gross misalignment by virtually increasing laser detector size.
Data protection ensures your data is there when you need it with auto save and resume capability.
Computer | |
CPU | Intel XScale PXA270 running at 312 MHz. |
Memory | 64 MB RAM, 64 MB flash. |
Display | Type: TFT, transmissive (sunlight-readable), 65,535 colors, backlit LED. |
Integrated light sensor for automated adjustment of the brightness to the display according to the lighting conditions which extends battery life. | |
Resolution: 320 x 240 pixel; Dimensions: 89 mm (3.5 in) diagonal. |
|
Keyboard elements: Setup, measure, diagnose, menu, clear, enter, back keys, navigation cursor cross, alphanumeric keyboard and on/off button. | |
LED indicators | Multicolor LED for laser status and alignment condition. |
Multicolor LED for battery status. | |
Power supply | Integrated Lithium-ion polymer rechargeable battery: 7.4 V/ 2.6 Ah (for optional computer) with typical operating time of 17 hours (based upon an operating cycle of 33 % measurement, 33 % computation and 33 % 'sleep' mode). |
External interface | USB host and USB device (slave). |
Integrated wireless communication, Class 1, transmitting power 100 mW. | |
RS232 (serial) for sensor. | |
AC adapter/charger socket. | |
Environmental protection | IP 65 (dustproof and water spray resistant), shockproof. |
Relative humidity 10 % to 90 %. | |
Operating temperature | -10 °C to 50 °C (14 °F to 122 °F). |
Storage temperature | -20 °C to 60 °C (-4 °F to 140 °F). |
Dimensions | 220 mm x 165 mm x 45 mm (8.7 in x 6.5 in x 1.8 in). |
Weight | 742 g (1.64 lb). |
Sensor | |
Measurement principle | Coaxial, reflected laser beam. |
Environmental protection | IP 67 (submersible, dustproof). |
Ambient light protection | Yes. |
Storage temperature | -20 °C to 80 °C (-4 °F to 176 °F). |
Operating temperature | 0 °C to 55 °C (32 °F to 131 °F). |
Dimensions | 107 mm x 70 mm x 49 mm (4 1/4 in x 2 3/4 in x 2 in). |
Weight | 177 g (6 1/2 oz). |
Laser | Type: Ga-Al-As semiconductor laser. |
Wavelength (typical) 675 nm (red, visible). | |
Safety class: Class 2, FDA 21 CFR 1000 and 1040. | |
Beam power: < 1 mW. | |
Safety precautions: Do not look into laser beam. | |
Detector | Measurement area: unlimited, dynamically extendible (U.S. Patent 6,040,903). |
Resolution: 1 μm; Accuracy (avg): > 98 %. | |
Inclinometer | Measurement range: 0° to 360°; Resolution: < 1°. |
Prism | |
Type | 90° roof prism; Accuracy (avg): > 99 %. |
Environmental protection | IP 67 (submersible, dustproof). |
Operating temperature | -20 °C to 60 °C (-4 °F to 140 °F). |
Storage temperature | -20 °C to 80 °C (-4 °F to 176 °F). |
Dimensions | 100 mm x 41 mm x 35 mm (4 in x 1 5/8 in x 1 3/8 in). |
Weight | 65 g (2 1/2 oz.). |
Carrying Case | |
Dimensions | 565 mm x 343 mm x 127 mm (22 1/4 in x 13 1/2 in x 5 in). |
Weight, including all standard parts | 5.6 kg (12.3 lb). |
COMPONENT |
DESCRIPTION | PART No. | ||
Fluke-830/MAGNET | Compact Magnetic Sensor/Prism Mounting Bracket Set. | 4528249 | ||
Fluke 830/SHIMS | Precision Alignment Shim Kit. | 4551330 |