- settings_phone Telephone: 02890 830302
- mail belfast@cuthbertsonlaird.co.uk
- EUR €
- GBP £
Fluke 810 Vibration Tester
Includes: Tri-axial accelerometer, magnet mount, mounting pad kit with adhesive, accelerometer, quick-disconnect cable, Laser tachometer and storage pouch, Smart battery pack with cable and adapters, Shoulder strap and adjustable hand strap, Viewer PC software, Mini USB to USB cable, Getting Started Guide, quick reference guide, Users Manual CD-ROM & carrying case.
Our pages are encrypted and protected from cyber-attack.
Payment Card Industry Data Security Standard (PCI DSS) Compliant.
TLS (SSL) - all data/information is secure from interception.
The Fluke 810 Vibration Tester is the most advanced troubleshooting tool for mechanical maintenance teams who need an answer now. The unique diagnostic technology helps you quickly identify and prioritize mechanical problems, putting the expertise of a vibration analyst in your hands.
Use a simple step-by-step process to report on machine faults the first time measurements are taken, without prior measurement history. The combination of diagnoses, severity and repair recommendations help you make informed maintenance decisions and address critical problems first.
FEATURES
On-board diagnosis and location of the four most common standard mechanical faults.
Fault severity scale with four severity levels.
Prioritized repair recommendations.
Diagnostic details include cited peaks and vibration spectra.
Context Sensitive Help.
2 GB expandable on-board memory.
Data export (via USB connection) for more detailed analysis.
Self-test function.
Laser tachometer for accurate machine running speed.
100 mV/g TEDS triaxial accelerometer.
Data storage and tracking with included Viewer Software.
Colour LCD display.
Diagnostic Specs | |
---|---|
Standard Faults | Unbalance, looseness, misalignment and bearing failures. |
Machine Rotational Speed Range | 200rpm to 12000rpm. |
Diagnostic Details | Plain-text diagnosis, fault severity (slight, moderate, serious, extreme), repair details, cited peaks, spectra). |
Electrical Specifications | |
Ranging | Automatic. |
A/D Converter | 4 channel, 24 bit. |
Usable Bandwidth | 2 Hz to 20 kHz. |
Sampling | 51.2 Hz. |
Digital Signal Processing Functions | Automatically configured anti-alias filter, high-pass filter, decimation, overlapping, windowing, FFT and averaging. |
Sampling Rate | 2.5 kHz to 50 kHz. |
Dynamic Range | 128 dB. |
Signal to Noise Ratio | 100 dB. |
FFT Resolution | 800 lines. |
Spectral Windows | Hanning. |
Frequency Units | Hz, orders, cpm. |
Amplitude Units | in/sec, mm/sec, Vdb (US), VdB (Europe). |
Non-Volatile Memory | SD micro memory card, 2GB internal + user accessible slot for additional storage. |
General Specifications | |
Dimensions (H x D x W) | 18.56 x 7.00 x 26.72 cm (7.30 x 2.76 x 10.52"). |
Weight (with battery) | 1.9 kg (4.2lbs). |
Display | ¼ VGA, 320 x 240 colour (5.7" diagonal) TFT LCD with LED backlight. |
Input/Output Connections | Triaxial Sensor Connection: 4 pin M12 Connector Single Axis Sensor: BNC connector Tachometer: Mini DIN 6 Pin Connector PC: Mini 'B' USB (2.0) Connector. |
Battery | Battery type: lithium-ion, 14.8 V, 2.55 Ah Battery charging time: 3 hours Battery life: 8 hours (under normal conditions). |
AC Adapter | Input voltage: 100 V AC to 240 V AC Input frequency: 50/60 Hz. |
Operating System | WinCE 6.0 Core. |
Language Support | English, French, German, Italian, Japanese, Portugese, Simplified Chinese, Spanish. |
Warranty | 3 years. |
Environmental Specifications | |
Operating Temperature | 0 to 50°C (32 to 122°F). |
Storage Temperature | -20 to 60°C (-4°F to 140°F). |
Operating Humidity | 10 to 95% RH (non-condensing). |
Agency Approvals | CHINA RoHS, CSA, CE, C TICK, WEEE. |
Electromagnetic Compatibility | EN 61326-1: 2001, EN 61010-1: 2001 2nd ed. |
Sensor Specifications | |
Sensor type | Accelerometer. |
Sensitivity | 100 mV/g (±5%, 25°C). |
Acceleration Range | 80g peak. |
Amplitude Nonlinearity | 1%. |
Frequency Response | Z: 2 - 7000Hz ±3 dV X, Y: 2 to 5000Hz±3 dB. |
Power Requirement (IEPE) | 18 V DC to 30 V DC, 2 mA to 10 mA. |
Bias Output Voltage | 12 V DC. |
Grounding | Case grounded. |
Sensing Element Design | PZT ceramic/shear. |
Case Material | 316L stainless steel. |
Mounting | 10-32 captive socket head screw, 2-pole rare earth magnet (48lbs pull strength). |
Output Connector | 4-pin, M12. |
Mating Connector | M12-F4D. |
Non-Volatile Memory | TEDS 1451.4 compatible. |
Vibration Limit | 500 g peak. |
Shock Limit | 5000 g peak. |
Electromagnetic Sensitivity, Equivalent g | 100 μg/gauss. |
Sealing | Hermetic. |
Temperature Range | -50 to 120°C (-58 to 248°F) ±7%. |
Warranty | 1 year. |
Tachometer Specifications | |
Dimensions | 2.86 x 12.19 cm (1.125 x 4.80"). |
Weight | 96 g (3.4 oz) with cable. |
Power | Powered by 810 vibration tester. |
Detection | Laser diode class 2. |
Range | 6.0 to 99,999 rpm. |
Accuracy | 6.0 to 5999.9 rpm: ±0.01% and ± 1 digit 5999.9 to 99999 rpm: ±0.05% and ± 1 digit. |
Resolution | 0.1 rpm. |
Effective Range | 1 cm to 100 cm (0.4 to 39.27"). |
Response Time | 1 second (>60 rpm). |
Controls | Measure on/off transparent button. |
Interface | 6 pin mini DIN. |
Cable Length | 50 cm (19.586"). |
Fluke 810 Warranty | 1 year. |