Includes: Test leads, alligator clips, holster, temperature probe, 9V battery (installed), CD-ROM (Fluke 87V users manual & technical notes and operators guide).
Our pages are encrypted and protected from cyber-attack.
Payment Card Industry Data Security Standard (PCI DSS) Compliant.
TLS (SSL) - all data/information is secure from interception.
When productivity is on the line and you need to solve problems fast, the Fluke 87V delivers the accuracy and advanced troubleshooting capabilities you need. Designed specifically to handle complex signals, the Fluke 87V industrial multimeter, allows you to gain productivity by taking the guesswork out of drive system troubleshooting even in loud, high energy, and high altitude locations.
The Fluke 87V has improved measurement functions, troubleshooting features, resolution and accuracy to solve more problems on motor drives, in plant automation, power distribution, and electro-mechanical equipment.
The Fluke 87 Series V has a unique function for accurate voltage and frequency measurements on adjustable speed motor drives and other electrically noisy equipment.
FEATURES
Voltage DC | |
Maximum Voltage | 1000 V. |
Accuracy | ±(0.05% + 1). |
Maximum Resolution | 10 μV. |
Voltage AC | |
Maximum Voltage | 1000 V. |
Accuracy | ±(0.7% + 2) true RMS. |
AO Bandwidth | 20kHz with low pass filter; 3 dB @ 1k Hz. |
Maximum Resolution | 0.1 mV. |
Current DC | |
Maximum Current | 10 A (20 A for 30 seconds max). |
Accuracy | ±(0.2% + 2). |
Maximum Resolution | 0.01 μA. |
Current AC | |
Maximum Current | 10 A (20 A for 30 seconds max). |
Accuracy | ±(1.0%+2) true RMS. |
Maximum Resolution | 0.1 μA. |
Resistance | |
Max Resistance | 50 MΩ. |
Accuracy | ±(0.2% + 1). |
Maximum Resolution | 0.1 Ω. |
Capacitance | |
Maximum Capacitance | 9999 μF. |
Accuracy | ±(1%+2). |
Maximum Resolution | 0.01 nF. |
Frequency | |
Maximum Frequency | 200 kHz. |
Accuracy | ±(0.005%+1). |
Maximum Resolution | 0.01 Hz. |
Duty Cycle | |
Maximum Duty Cycle | 99.9%. |
Accuracy | ±(0.2% per kHz + 0.1%). |
Maximum Resolution | 0.1%. |
Temperature | |
Measurement Ranges | -200 to 1090° C -328 to 1994° F (excluding probe). |
Conductance | |
Maximum | 60.00 nS. |
Accuracy | ±(1.0% + 10). |
Maximum Resolution | 0.01 nS. |
Diode | |
Range | 3 V. |
Resolution | 1 mV. |
Accuracy | ±(2%+1). |
Duty Cycle | |
Accuracy | Within ±(0.2% per kHz +0.1%). |
Environmental Specifications | |
Operating Temperature | -20 to +55° C. |
Storage Temperature | -40 to +60° C. |
Humidity (Without Condensation) | 0 to 90% (0 to 35° C) 0 to 70% (35 to 55° C). |
Operating Altitude | 2000 m. |
Safety Specifications | |
Overvoltage Category | EN 61010-1 to 1000V CAT III, 600V CAT IV. |
Agency Approvals | UL, CSA, T-V, VDE listed. |
Mechanical/General Specifications | |
Dimensions | 201 x 98 x 52mm (with holster). |
Weight | 355g (624g with holster). |
Display | Digital - 6000 counts, updates 4/sec (19999 counts in high resolution mode) Analogue - 32 segments, updates 40/sec Frequency - 19999 counts, updates 3/sec at >10Hz. |
Fluke 87V Warranty | Lifetime. |
Battery Life | Alkaline - 400 hours typical (without backlight). |
Shock | 1m drop-tested per IEC 61010-1: 2001. |
Vibration | Per MIL-PRF-28800 for a class 2 instrument. |