Metrel MI 3311 GammaPAT Pro PAT Tester
Includes: MI 3311 GammaPAT, 2m IEC cable, Earth Bond Lead, 12 V battery charging adapter, Rechargeable NiMH AA batteries (6 pcs), USB cable, Short instruction manual, CD (including handbook, long user manual, SW), Calibration certificate, License for PC SW PATLink PRO, License for PATLink Android.
Our pages are encrypted and protected from cyber-attack.
Payment Card Industry Data Security Standard (PCI DSS) Compliant.
TLS (SSL) - all data/information is secure from interception.
The Metrel GammaPAT Pro is a downloading multifunctional PAT Tester which can store up to 1500 test results in the internal memory. The results, with parameters, can then be downloaded into a PC and a test certificate produced. The GammaPAT Pro is an upgraded version of the GammaPAT Lite.
The Pro version comes with up to 50 pre-programmable VDE compatible auto-sequences for speeding up testing. It has a built-in calibration checkbox and large Red/Green LED lights that indicate a PASS or FAIL evaluation of the appliance being tested.
The GammaPAT Pro is the ideal instrument to use in hard-to-reach area's due to its built-in charger & rechargeable batteries. The instrument is supplied with a set of rechargeable NiMH batteries.
FUNCTIONS200mA Continuity test.
Insulation resistance.
Insulation resistance of isolated accessible conductive parts.
Substitute leakage current.
Substitute leakage current of isolated accessible conductive parts.
IEC lead polarity test.
TRMS voltage.
Functional and visual inspection.
Earth Continuity | |||
---|---|---|---|
Range | Resolution | Accuracy | |
0.00Ω to 19.99Ω | 0.01Ω | ±(5% reading + 3 digits). | |
20.0Ω to 199.9Ω | 0.1Ω | Indication only. | |
200Ω to 1999Ω | 1Ω | Indication only. | |
Test Currents | 200mA into 2.00Ω. | ||
Open Circuit Voltage | <9V AC. | ||
PASS Levels | 0.10Ω, 0.20Ω, 0.30Ω, 0.40Ω, 0.50Ω, 0.60Ω, 0.70Ω, 0.80Ω, 0.90Ω, 1.00Ω, 1.50Ω, 2.00Ω. | ||
Test Duration | 2s, 5s, 10s, 30s, 60s, 120s, ---s. | ||
Test Method | 2 wire measurement. | ||
Insulation Resistance | |||
Range | Resolution | Accuracy | |
0.00MΩ to 19.99MΩ | 0.01MΩ | ±(5% of reading + 3 digits) | |
20.0MΩ to 49.9MΩ | 0.1MΩ | ||
50MΩ to 199.9MΩ | 0.1MΩ | Indication only. | |
Nominal Voltages | 250V DC, 500V DC (-0%, +10%). | ||
Measuring Current | min. 1mA at 250kΩ (250V, 500kΩ (500V). | ||
Short Circuit Current | Max 2.0mA. | ||
Pass Levels | 0.01MΩ, 0.10MΩ, 0.25MΩ, 0.30MΩ, 0.50MΩ, 1MΩ, 2MΩ, 4MΩ, 7MΩ, 10MΩ, ---MΩ. | ||
Test Duration | 2s, 3s, 5s, 10s, 30s, 60s, 120s, ---s. | ||
Substitute Leakage Current | |||
Range | Resolution | Accuracy | |
0.00mA to 9.99mA | 0.001mA | ±(5% of reading + 3 digits) | |
10.0mA to 19.9mA | 0.1mA | ||
Open Circuit Voltages | Less than 50 V AC at rated mains voltage. | ||
Short Circuit Current | <2.5 mA. | ||
Pass Levels Substitute Leakage | 0.25 mA, 0.50 mA, 0.75 mA, 1.00 mA, 1.50 mA, 2.00 mA, 2.25 mA, 2.50 mA, 3.50 mA, 4.00 mA, 4.50 mA, 5.00 mA, 5.50 mA, 6.00 mA, 7.00 mA, 8.00 mA,9.00 mA, 10.0 mA, 15.0 mA, --- mA. | ||
Test Duration | 2 s, 3 s, 5 s, 10 s, 30 s, 60 s, 120 s, --- s. | ||
General Specifications | |||
Polarity test | Test voltage < 50 VAC. | ||
Power supply | 6 x 1.2 V NiMH rechargeable batteries, type AA. | ||
Overvoltage Category | CAT II / 300 V. | ||
Display | 128 x 64 dots matrix display with backlight. | ||
Protection Degree Case | IP40. | ||
Protection Degree Test Connectors | IP20. | ||
Dimensions | 140 x 80 x 230 mm. | ||
Weight | 0,86 kg without battery cells. |