loading spinner
Megger PAT320 PAT Tester
  • Megger PAT320 PAT Tester
  • Megger PAT320 PAT Tester

Megger PAT320 PAT Tester

Megger approved distributor and service centre.

Product shown at RRP. Telephone (Belfast) 02890 830302 for our sale price.

Includes: Carry case, Quick-start guide, Black test lead set with probe and clip, IEC lead 0.5 m (Extension lead adaptor), Warranty card, Owners CD manual, PP3 9 V NiMH rechargeable battery.

£1,355.00
Tax excluded
Quantity
  HTTPS Secure

Our pages are encrypted and protected from cyber-attack.

  Compliant

Payment Card Industry Data Security Standard (PCI DSS) Compliant.

  Protected

TLS (SSL) - all data/information is secure from interception.

The Megger PAT320 is the PAT tester if you need high productivity with a tough and easy to use instrument. If you are moving into PAT testing for the first time or you don’t want the complexity of database management, PAT320 is ideal for you.

Simple push-button operation make the Megger PAT320 very fast and easy to use. All regulatory test requirements are supported, including Class I and Class II tests. IEC power leads and extension leads are easily connected. An automatic mode is available for Class I and Class II testing.

FEATURES

Simple manual or automatic testing.
230V and 110V operation.
Virtual continuous operation.
Bond testing at 25 A,10 A and 200 mA.
Full colour display.
Tests portable RCDs and extension leads.
Differential, touch and substitute leakage testing.

PAT320 & PAT350 Product Demo

Megger PAT320 Specifications
Electrical Supply Range
230 V AC 230 V AC ±10%.
110 V AC 110 V AC ±10%.
Supply Measurement
Voltage ±2% ± 1 V
Frequency ±1% ± 0.1 Hz.
Bond Test
Open Circuit Voltage 9 V AC ±10% ±0.1 V (Supply: 230 V 50 Hz).
10 A Bond Test Current 10 A rms ±20% ±0.5 A into 0.1 Ω.
25 A Bond Test Current 25 A rms ± 5% ± 0.5 A into 0.1 Ω.
Earth Bond Resistance Accuracy ±5% ± 3 digits (0 to 0.49 Ω)
±5% ± 5 digits (0.5 to .99 Ω).
Earth Bond Resistance Resolution 10 mΩ (0 to 1.99 Ω).
Display Range 0 to 1.99 Ω.
Bond Test Nulling Up to 1.00 Ω.
Adjustable Test Duration User selectable from 1 sec to 20 sec.
Continuity Test
Continuity Test Voltage 4.0 V DC -0% +10% (open circuit).
Continuity Test Current 200 mA -0% + 10% ± 5 mA (into 2 Ω load).
Continuity Resistance Accuracy ±5% ±3 digits (0 to 0.49 Ω)
±5% ±5 digits (0.5 to .99 Ω).
Continuity Resistance Resolution 10mΩ (1 to 19.99 Ω).
Display Range 0 to 19.99 Ω.
Continuity Test Nulling Up to 9.99 Ω.
Test Duration User selectable from 1 sec to 20 sec.
Note: The continuity test is a DC test performed automatically in both positive and negative directions. The average of the two results is shown.
Insulation Test
Insulation Test Voltage 250 V DC -0%/+25% open circuit
500 V DC -0%/+25% open circuit
(500 V DC across 0.5 MΩ).
Insulation Resistance Accuracy (230 V) ±2% ±5 digits (0 to 19.99 MΩ)
±5% ± 10 digits (20 to 99.99 MΩ).
Insulation Resistance Accuracy (110 V) ±5 ±5 digits (0 to 10 MΩ).
Insulation Resistance Resolution 0.01 MΩ (0.10 to 99.99 MΩ).
Display Range 0 to 99.99M Ω.
Test Duration User selectable from 1 sec to 1 minutes.
Substitute Leakage Test
Test Voltage 40 V AC ±10%.
Test Frequency Nominal mains 50/60 Hz.
Leakage Current Accuracy ±5% ± 5 digits.
Leakage Current Resolution 0.01 mA.
Display Range 0 to 19.99 mA.
Test Duration User selectable from 1 sec to 1 minute
Reading corrected to 230 V + 10% or 110 V +10% AC.
Differential Leakage Current
Test Voltage Nominal mains 110 V/230 V AC.
Test Frequency Nominal mains 50/60 Hz.
Differential Leakage Current Accuracy ±5% ± 5 digits.
Differential Leakage Current Resolution 0.01 mA.
Display Range 0 to 19.99 mA
Reading corrected to 230 V +10 % or 110 V + 10% AC.
Touch Current Test
Test Voltage Nominal mains 115 V/230 V AC.
Test Frequency Nominal mains 50/60 Hz.
Touch Current Accuracy ±5% ±5 digits.
Touch Current Resolution 0.01 mA.
Display Range 0 to 10 mA.
Test Duration User selectable from 1 sec to 5 sec
Reading corrected to 230 V + 10% or 110 V + 10% AC.
Operational Test
Test Voltage Nominal mains 110 V/230 V AC.
Accuracy ±5% ±10 digits (0 to 99 VA)
±5% ±50 digits (100 to 999 VA)
±5% ±100 digits (1000 to 3700 VA).
Resolution 1 VA (0 to 3700 VA).
Display Range 0 to 3.99 KVA
Reading corrected to 230 V or 110 V AC
Results show load VA.
Extension Lead Test
Polartity Test Voltage 12 V
Polarity Leak OK
Live neutral S/C
Live neutral reversed
Live/neutral O/C.
Portable RCD Test
RCD Test Voltage Nominal mains 110/230 V.
RCD Test Frequency 50 Hz.
Test Current Accuracy -8% to -2% (1/2 x I)
±2% to +8^ (1 x 1,5 x I).
Trip Time Accuracy ±1% ±5 digits.
Trip Time Resolution 0.1ms.
Display Range 0 to 1999 ms (1/2 x I)
0 to 300 ms (1 x I)
0 to 40 ms (5 x I).
Fuse Test
Test Voltage 3.3 V.
Warning Audible Beep if fuse is ok.
Dimensions (with case) 190 (H) x 400 (D) x 290mm (W).
Weight (instrument only) 4.5 kg.
Megger PAT320 warranty 1 year.
Megger
1000-740

Download

Megger PAT300 Series Datasheet

PDF Specifications of the Megger PAT320 & PAT350 Portable Appliance Testers.

Download (232.43k)
COMPONENT
DESCRIPTION PART No.
110 V Adapt 110 V mains lead adaptor. 1000-766
Plug Adapt Plug adaptor IEC C6 - C13. 2000-551
Ext lead 110 V Extension lead adaptor. 6220-639
Adapt 415 V adaptor lead (4-pin) to BS1363 (16 A). 1000-767
Adapt 415 V adaptor lead (5 pin) to BS1363 (16 A). 1000-770
Protect Screen protector (2). 1002-572
Pass Labels Roll of 1000 PASS test labels. 1000-971
Fail Labels Roll of 1000 FAIL test labels. 1001-227