Fluke 729-300G Automatic Pressure Calibrator
Includes: Fluke 729 Calibrator without wireless communication, soft case, stackable test leads, AC280 hook clips, alligator clips, test probes, magnetic hanger kit, carrying strap, quick start guide, safety sheet, power supply, rechargeable battery (installed), hose kit with push fit adapters, hanging clip, USB cable, 1/8 in FNPT to 1/4 in FNPT adapter, 1/8 in FNPT to F-M20 adapter, 1/8 in FNPT to 1/4 in FBSP adapter, PTFE tape, (2) sintered filters, water trap drain and valve tuning hoses.
Our pages are encrypted and protected from cyber-attack.
Payment Card Industry Data Security Standard (PCI DSS) Compliant.
TLS (SSL) - all data/information is secure from interception.
The Fluke 729 Automatic Pressure Calibrator has been designed specifically with process technicians in mind to simplify the pressure calibration process and provide faster, more accurate test results. Technicians know that calibrating pressure can be a time consuming task, but the 729 makes it easier than ever with an internal electric pump that provides automatic pressure generation and regulation in an in an easy-to-use, rugged, portable package.
The ideal portable pressure calibrator, the 729 allows you to simply type in a target pressure, and the calibrator will automatically pump to the desired set-point. Then, internal fine adjustment control automatically stabilises the pressure at the requested value.
The Fluke 729 can also automatically test multiple pressure test points and automatically document the results. Calibration is as easy as typing in the starting and ending pressure and the number of test points and tolerance level. The 729 does the rest by documenting the applied pressure, measured mA and % error for each test point. The bright color graphical display will flag out of tolerance test results in red.
HART communication enables mA output trim, trim to applied values and pressure zero trimming of HART pressure transmitters. You can also do light configuration tasks such as changing a transmitter tag, measurement units and ranging. Other supported HART commands include setting fixed mA outputs for trouble-shooting, read device configuration and variables and read device diagnostics.
Upload and manage documented calibration results with DPCTrack2™ Calibration Management Software, making it easy to manage your instrumentation, create scheduled tests and reports, and manage calibration data.
FEATURES
Automatic pressure generation and regulation to 300 psi.
Easily document the process using onboard test templates.
Automatic internal fine-pressure adjustment.
Measure, source and simulate 4 to 20 mA signals.
24V loop power for powering transmitters for tests.
Bright dual/triple-channel color graphical display.
HART communication for testing HART smart transmitters.
Built in leak testing for verifying test setups for leakage.
Rugged portable design with standard 3-year warranty.
Fluke Connect® App compatibility (dependent on model).
Measure temperature with optional 720RTD probe.
Measure Vdc for testing 1 V dc to 5 V dc output transmitters.
Compatible with 700 Series and 750 Series pressure modules.
Upload documented test results to DPCTrack2™ Calibration Management Software.
Innovative semi-rigid carrying case designed for field work.
Pressure | |||
BAR range | -0.8273 to 20.6843 bar. | ||
PSI range | -12.000 to 300.000 psi. | ||
kPa range | -82.73 to 2068.43 kPa. | ||
Comment | No wireless communication. | ||
Electrical Specification | |||
All specifications are valid to 110% of range, except 24 mA source and simulate which are valid to 100% of range. | |||
Ranges | |||
mA measure, source and simulate | 0 mA to 24 mA. | ||
Volts dc measure | 0 V dc to 30 V dc. | ||
Resolution | |||
mA dc source, simulate and measure | 1 μA. | ||
Voltage dc measurement | 1 mV. | ||
Accuracy | 0.01% ±2 LSD all ranges (at 23 °C ±5 °C). | ||
Stability | 20 ppm of full scale /°C from -10 °C to +18 °C and 28 °C to +50 °C. | ||
mA simulate external voltage requirement | 12 V dc to 30 V dc. | ||
Loop compliance voltage | 24 V dc @ 20 mA. | ||
mA simulate external voltage requirement | 12 V dc to 30 V dc. | ||
Temperature measurement only/100 Ω Pt(385) RTD | -50 °C to 150 °C (-58 °F to 302 °F). | ||
Temperature resolution | 0.01 °C (0.01 °F). | ||
Temperature accuracy | ±0.1 °C (0.2 °F) ±0.25 °C (±0.45 °F) combined uncertainty when using 720 RTD probe (optional accessory). | ||
Drive capability | 1200 Ω without HART resistor, 950 Ω with internal HART resistor. | ||
General | |||
Operating temperature | -10 °C to 50 °C for measurement, 0 °C to 50 °C for pressure control. | ||
Operating temperature with battery | -10 °C to 40 °C. | ||
Battery will only charge to 40 °C. | |||
Storage temperature | -40 °C to 60 °C. | ||
Dimensions (H x W x L) | 7 x 27.94 x 17.27 cm (2.75 x 11 x 6.8 in). | ||
Weight | 6.5 lbs., 2.95 kg. | ||
Enclosure rating | IP54. | ||
Fluke 729-150g warranty | Two-years (standard), extended warranties are available. |