loading spinner
Fluke 376 FC True-rms AC/DC Clamp Meter with iFlex
  • Fluke 376 FC True-rms AC/DC Clamp Meter with iFlex
  • Fluke 376 FC
  • Fluke 376 FC True-rms AC/DC Clamp Meter with iFlex
  • Fluke 376 FC

Fluke 376 FC True-rms AC/DC Clamp Meter with iFlex

Fluke authorised distributor and calibration house.

Includes: Fluke 376FC, 18-inch iFlex® Flexible Current Probe, TPAK magnetic hanging strap, Soft carrying case, TL75 test leads, Two AA Alkaline batteries, Coated instruction card, Safety information sheet.

Quantity
  HTTPS Secure

Our pages are encrypted and protected from cyber-attack.

  Compliant

Payment Card Industry Data Security Standard (PCI DSS) Compliant.

  Protected

TLS (SSL) - all data/information is secure from interception.

The Fluke 376 FC Wireless True-rms AC/DC Clamp Meter offers improved performance perfect for a wide range of current measurement situations. With true-rms voltage and current measurements, the Fluke 376 can read up to 1000 V and 1000 A in both ac and dc modes.

The Fluke Connect® enabled 376 FC Clamp Meter logs measurements to pinpoint intermittent faults precisely without the need for the technician to be present. Those measurements are then wirelessly transmitted to the Fluke Connect app on smartphones or tablets and automatically uploaded to the cloud, keeping technicians outside the arc flash zone and away from dangerous moving machinery, thus improving safety.

Additionally, the Fluke 376 FC includes the iFlex flexible current probe, which expands the measurement range to 2500 A ac while providing increased display flexibility, ability to measure around awkward sized conductors and improved wire access. The iFlex probe fits neatly into the bottom of the unit and is an ideal product for bending around conductors that simply aren't possible to test using a conventional clamping system.

FEATURES:

Connect your meter to your smartphone with Fluke Connect Measurements.
Read measurements on your phone at a safe distance, wearing less PPE while your meter takes all the risks.
Record results directly to your phone and the Cloud.
Capture intermittent faults while performing other tasks.
Create and share reports from the field via email, or converse in real-time with ShareLive™ video calls.
iFlex flexible current probe expands the measurement range to 2500 A ac; provides access to large conductors in tight spaces.
TPAK magnetic hanging strap.
Integrated VFD low pass filter for accurate motor drive measurements.
Proprietary inrush measurement technology to filter out noise and capture motor starting current.
CAT IV 600 V, CAT III 1000 V safety rating.
Three-year warranty.

Fluke 376 FC Specifications
AC Current Via Jaws
Range 999.9 A.
Resolution 0.1 A.
Accuracy 2% ±5 digits (10 Hz to 100 Hz)
2.5% ±5 digits (100-500 Hz).
Crest Factor (50/60 Hz) 3 @ 500 A
2.5 @ 600 A
Add 2% for C.F. >2.
AC Current via Flexible Current Probe
Range 2500 A.
Resolution 0.1 A (≤ 600 A)
1 A (≤ 2500 A).
Accuracy 3% ±5 digits (5 – 500 Hz).
Crest Factor (50/60Hz) 3.0 at 1100 A
2.5 at 1400 A
1.42 at 2500 A
Add 2% for C.F. > 2.
DC Current
Range 600.0 A.
Resolution 0.1 A.
Accuracy 2% ±5 digits.
AC Voltage
Range 1000 V.
Resolution 0.1 V (≤600.0 V)
1 V (≤1000 V).
Accuracy 1.5% ±5 digits (20 Hz to 500 Hz).
DC Voltage
Range 1000 V.
Resolution 0.1 V (≤600.0 V)
1 V (≤1000 V).
Accuracy 1% ±5 digits.
mV DC
Range 500.0 mV.
Resolution 0.1 mV.
Accuracy 1% ±5 digits.
Frequency Via Jaw
Range 5.0 Hz to 500.0 Hz.
Resolution 0.1 Hz.
Accuracy 0.5% ±5 digits.
Trigger Level 5 Hz to 10 Hz, ≥10 A
10 Hz to 100 Hz, ≥5 A
100 Hz to 500 Hz, ≥10 A.
Frequency via Flexible Current Probe
Range 5.0 Hz to 500.0 Hz.
Resolution 0.1 Hz.
Accuracy 0.5% ±5 digits.
Trigger Level 5 Hz to 20 Hz, ≥25 A
20 Hz to 100 Hz, ≥20 A
100 Hz to 500 Hz, ≥25 A.
Resistance
Range 60 kΩ.
Resolution 0.1 Ω (≤600 Ω)
1 Ω (≤6000 Ω)
10 Ω (≤60 kΩ).
Accuracy 1% ±5 digits.
Capacitance
Range 1000 μF.
Resolution 0.1 μF (≤ 100 μF)
1 μ F (≤ 1000 μF).
Accuracy 1% ±4 digits.
Mechanical Specifications
Maximum voltage between any terminal and earth ground 1000 V.
Batteries 2 AA, NEDA 15A, IEC LR6.
Operating Temperature -10 °C to +50 °C.
Storage Temp -40 °C to +60 °C.
Operating Humidity Non condensing (< 10 °C)
≤ 90 % RH (at 10 °C to 30 °C)
≤ 75 % RH (at 30 °C to 40 °C)
≤ 45 % RH (at 40 °C to 50 °C).
Operating Altitude 3000 meters.
Storage Altitude 12,000 meters.
Dimensions 249 x 85 x 45 mm.
Weight 395 g
Jaw Opening 34 mm.
Flexible current probe diameter 7.5 mm.
Flexible current probe cable length
(head to electronics connector)
1.8 m.
Safety IEC 61010-1, Pollution Degree 2
IEC 61010-2-032: CAT III 1000 V / CAT IV 600 V
IEC 61010-2-033:CAT III 1000 V / CAT IV 600 V.
IP Rating IEC 60529: IP30, non-operating.
Radio Frequency Certification FCC ID T68-FBLE IC:6627A-FBLE.
Fluke 376 FC warranty 3 years.
FLU376FC

Download

Fluke 370FC Datasheet

PDF Specifications of the Fluke 373FC, 374FC & 375FC Series of Clamp Meters.

Download (1.27M)
COMPONENT
DESCRIPTIONPART No.
AC220SureGrip™ Alligator Clip Set.1610103
AC87Heavy Duty Bus Bar Clip Set.1278079
TP1Slim Reach Test Probe (flat blade).3971265
TL75Hard Point™ Test Lead Set.3971218
TPAKToolPak™ Magnetic Meter Hanger Kit
Includes:
9 inch hook and loop strap
Universal hanger clip
Hook hanger for non magnetic surfaces
Strong magnet.
1281997
i2500-18 iFlex®Flexible Current Probes.3676405
i2500-10 iFlex®Flexible Current Probes.3676410

16 other products in the same category: