Fluke BT510 Battery Analyser
Includes: Fluke BT510 Battery Analyser, 4-Wire Test Pin (Set), BTL10 Basic Test Lead (Set), Lithium Ion Battery, AC Charger, USB Cable, Shoulder Strap, Belt Strap, Magnetic Hanging Strap, Fluke Battery Management Software on CD-ROM, Soft Carrying Case, 2 x Spare Fuses.
Our pages are encrypted and protected from cyber-attack.
Payment Card Industry Data Security Standard (PCI DSS) Compliant.
TLS (SSL) - all data/information is secure from interception.
The Fluke BT510 Battery Analyser is a multi-functional meter designed for the test and measurement of a stationary battery system. The Product can measure the battery internal resistance and voltages. These measurements can be used to determine the overall condition of the system. It can also measure electrical parameters for battery system maintenance, including dc voltage up to 600 V, ac voltage up to 600 V, and ripple voltage.
The Fluke BT510 provides two modes for different measurement purposes: Meter mode and Sequence mode. Meter mode lets you perform easy and fast measurements and save the measurement readings and timestamp to the BT510 memory. In this mode, the instrument measures battery internal resistance and voltage, dc voltage, ac voltage, and ripple voltage.
Sequence mode is designed for battery maintenance personnel who work between multiple test sites. In this mode, you can create a profile for each battery string to be tested. The profile specifies information such as user-defined test site, device type, serial number, battery quantity, and battery model. During the test, all test data, including battery resistance, voltage, and ripple voltage is stored in the profile. After a BT510 battery string test is completed, you can create a new profile for the next battery string or test site. You can also recall or delete the test data in a history profile. Each time you power on the tester, it is in Meter mode by default. METER MODE shows on the upper-left corner of the display.
FEATURES
Suitable for use in testing stationary batteries and battery backup systems of all types.
Tests resistance, battery voltage (AC/DC), ripple voltage and frequency.
Users can calculate the time a battery takes to drop to the cut-off voltage.
Comprehensive logging.
Logging software to analyse results and create reports.
USB port for download to PC.
CAT III 600V rated.
Functions | Range | Resolution | Accuracy | BT510 | BT520 | BT521 |
Battery Resistance / Strap Resistance1 | 3 mΩ | 0.001 mΩ | 1% + 8 | |||
30 mΩ | 0.01 mΩ | 0.8% + 6 | ||||
300 mΩ | 0.1 mΩ | 0.8% + 6 | ||||
3000 mΩ | 1 mΩ | 0.8% + 6 | ||||
Vdc | 6 V | 0.001 V | 0.09% + 5 | |||
60 V | 0.01 V | 0.09% + 5 | ||||
600 V | 0.1 V | 0.09% + 5 | ||||
1000 V | 1V | 0.09% + 5 | ||||
Vac (45 Hz to 500 Hz with 800 Hz filter) | 600 V | 0.1 V | 2% + 10 | |||
Frequency (displayed with Vac and Aac)2 | 500 Hz | 0.1 Hz | 0.5% + 8 | |||
AC voltage ripple (20KHz Max) | 600 mV | 0.1 mV | 3% + 20 | |||
6000 mV | 1 mV | 3% + 10 | ||||
Adc/Aac (with accessory Fluke i410) | 400 A | 1 A | 3.5% + 2 | |||
Temperature | 0°C to 60°C | 1°C | 2°C (4 °F) | |||
Meter mode | 999 records for each measurement position with time stamp. | |||||
Sequence mode | Up to 100 profiles and 100 profile templates (Each profile stores up to 450 batteries) with time stamp. | |||||
1 The measurement is based on ac injection method. The injected source signal is < 100 mA, 1 kHz. 2 Trigger level VAC: 10 mV, Aac: 10 A. |
Measurement Modes | BT510 | BT520 | BT521 |
Resistance (mΩ) | |||
Battery voltage | |||
Voltage dc | |||
Voltage ac and frequency (Hz) | |||
Ripple volt | |||
Temperature of negative battery post | |||
DC and ac current (and frequency) | |||
DMM mode | |||
Sequence mode | |||
Discharge measurement mode | |||
Automatic measurement save | |||
Wireless communication | |||
Memory view |
General Specifications |
||
---|---|---|
Operating temperature | 0°C to 40°C. | |
Storage temperature | -20°C to 50°C. | |
Lithium-ion battery charging temperature | 0°C to 40°C. | |
Operating humidity | Non-condensing (10°C). | |
<=80% RH (at 10°C to 30°C). | ||
<=75% RH (at 30°C to 40°C). | ||
Operating altitude | Sea level to 2000 meters. | |
Storage altitude | Sea level to 12,000 meters. | |
IP rating | IP40. | |
Radio | FCC Class A. | |
Vibration requirements | MIL-PRF-28800F: Class 2. | |
Drop test requirements | 1 meter. | |
Temperature coefficients | Add 0.1 x specified accuracy for each degree C above 28°C or below 18°C. | |
Safety compliance | 600 V CAT III. | |
EMC | IEC 61326. | |
ROHS | China, Europe. | |
Protection class 2 | Pollution Degree II. | |
Battery compliance | UN38.3. | |
UL2054. | ||
IEC62133. | ||
2G per IEC68-2-26, 25G, and 29. | ||
Dimensions (H x W x D) | 22 cm x 10.3 cm x 5.8 cm (9 in x 4 in x 2 in). | |
Weight | 850 g (1.9 lb). | |
Screen dimensions | 7.7 cm x 5.6 cm (3 in x 2.2 in). | |
Interface | USB mini. | |
Fluke BT510 Warranty | 3 years. |