Includes: The DPI 705E and DPI 705E-IS are supplied with a user guide and calibration certificate as standard.
Our pages are encrypted and protected from cyber-attack.
Payment Card Industry Data Security Standard (PCI DSS) Compliant.
TLS (SSL) - all data/information is secure from interception.
Pressure Range | Abs | Gauge | Diff | Std. Acc | High Acc | |
25 mbar / 10 inH2O / 2.5 kPa | - | - | ||||
70 mbar / 1 psi / 7 kPa | - | - | ||||
200 mbar / 3 psi / 20 kPa | - | - | ||||
350 mbar / 5 psi / 35 kPa | ||||||
700 mbar / 10 psi / 70 kPa | ||||||
1 bar / 15 psi / 100 kPa | ||||||
2 bar / 30 psi / 200 kPa | ||||||
3.5 bar / 50 psi / 350 kPa | - | |||||
7 bar / 100 psi / 700 kPa | - | |||||
10 bar / 150 psi / 1000 kPa | - | |||||
20 bar / 300 psi / 2 MPa | - | |||||
35 bar / 500 psi / 3.5 MPa | - | |||||
70 bar / 1000 psi / 7 MPa | - | |||||
100 bar / 1500 psi / 10 MPa | - | |||||
135 bar / 2000 psi / 13.5 MPa | - | |||||
200 bar / 3000 psi / 20 MPa | - | |||||
350 bar / 5000 psi / 35 MPa | - | - | ||||
700 bar / 10000 psi / 70MPa | - | - | ||||
Note: Do not apply pressure greater than 1 bar (16 psi) absolute to the negative port of differential pressure indicators. |
Working Pressure | 110% FS (alarm active beyond this range). |
Leak test | 1, 3 or 5 minute leak test. |
Media Compatibility | Media to be compatible with Stainless Steel and Hastelloy. |
Certification | |
---|---|
Shock and vibration | MIL-PRF-28800F for Class II equipment. 1 m Drop Tested @ -20°C (-4°F). |
EMC | BS EN 61326-1. |
Electrical safety | BS EN 61010-1 UL 61010-1. |
Pressure safety | Pressure equipment directive class SEP. UL61010 Safe to 2xFS. |
Approval | CE marked, RCM. |
Sealing | IP 54. |
RoHS | Compliant. |
General Specifications | |
Display | 16mm LCD with ±99999 readout. |
Operating temperature | -10 to 50°C (14 to 122°F). |
Storage temperature | -20 to 70°C (-4 to 158°F). |
Humidity | 0 to 90% RH non condensing. |
Alarm | User adjustable; high and low pressure alarms with visual and audible warning for 60 seconds. |
Battery | 4 x AA Alkaline/NiCd/NiMH cells. |
Dimensions | (L) 200 mm, (W) 95 mm, (D) 43 mm. |
Weight | 563 g maximum. |
DPI705E warranty | One-year. |
COMPONENT | DESCRIPTION | PART No. | ||
Case | DPI705E carry case. | IO705E-CASE | ||
Case (IS) | DPI705E carry case (IS). | IO705E-CASE-IS | ||
Strap | DPI705E Hanging Strap. | IO705E-STRAP | ||
PM700E Cable | PM700E Remote Sensor Cable 2.9M. | PM700E-CABLE | ||
Adaptor | Adaptor G1/8 Male to G1/4 Female. | IO-ADAPT-G1/4 | ||
Adaptor | Adaptor G1/8 Male to 1/4NPT Female. | IO-ADAPT-1/4NPT | ||
Adaptor | Adaptor G1/8 Male to 1/8NPT Female. | IO-ADAPT-1/8NPT | ||
QF Adaptor | G1/8M to Quick-fit Adaptor. | IO-ADAPT-QF | ||
Interface | RTD Interface only - RS485. | RTD-INTERFACE-485 | ||
Interface (IS) | RTD IS Interface only - RS485. | RTD-INTERFACE-IS | ||
PT100 Probe | RTD Interface with PT100 probe - RS485. | RTD-PROBE-485 | ||
PT100 Probe (IS) | RTD IS Interface with PT100 probe-RS485. | RTD-PROBE-IS | ||
M12 Connector | Field Wireable M12 connector 4-pin. | IO-RTD-M12CON | ||
M12 Ext. Lead | M12M to M12F 2m ext lead (6.5 ft) 4-wire. | IO-RTD-M12EXT | ||
RTD Probe | RTD Probe 150mm, PT100 steel Class A. | IO-RTD-PRB150 | ||
Hose Assembly 1m | 20 bar Hose Assembly 1 metre. | IOHOSE-NP1 | ||
Hose Assembly 2m | 20 bar Hose Assembly 2 metre. | IOHOSE-NP2 | ||
Hose Kit P1 | Pneumatic Hose Kit-1 metre. | IO620-HOSE-P1 | ||
Hose Kit P2 | Pneumatic Hose Kit-2 metres. | IO620-HOSE-P2 | ||
Hose Kit H1 | Hydraulic Hose Kit-1 metre. | IO620-HOSE-H1 | ||
Hose Kit H2 | Hydraulic Hose Kit-2 metres. | IO620-HOSE-H2 | ||
Hose Kit P1 (IS) | Pneumatic Hose Kit-1 metre (IS). | IO620-HOSE-P1-IS | ||
Hose Kit P2 (IS) | Pneumatic Hose Kit-2 metres (IS). | IO620-HOSE-P2-IS | ||
Hose Kit H1 (IS) | Hydraulic Hose Kit-1 metre (IS). | IO620-HOSE-H1-IS | ||
Hose Kit H2 (IS) | Hydraulic Hose Kit-2 metre (IS). | IO620-HOSE-H2-IS | ||
Adaptors BSP | Pressure Adaptor Set - BSP. | IO620-BSP | ||
Adaptors NPT | Pressure Adaptor Set - NPT. | IO620-NPT |