- settings_phone Telephone: 02890 830302
- mail belfast@cuthbertsonlaird.co.uk
- EUR €
- GBP £
Megger PAT150R With Rechargable Batteries
Includes: Continuity/earth bond test lead Probe & Croc Clip, Extension Lead Adaptor, AC Charger Adaptor, Mains Supply Cord, SELV/mains voltage test lead Red, Cal certificate, 8 x AA Batteries, 8 x rechargeable batteries, Instructions & Carry Case.
Our pages are encrypted and protected from cyber-attack.
Payment Card Industry Data Security Standard (PCI DSS) Compliant.
TLS (SSL) - all data/information is secure from interception.
Battery powered operation makes the PAT100s perfect for those locations where an electrical supply is not available, inconvenient or unsafe, especially building sites and warehouses. The PAT100 series conforms to all UK and European requirements for electrical safety testing.
The Megger PAT150 pat tester offers Portable RCD (PRCDs) testing at 10 mA and 30 mA, separate tests for continuity, insulation, mains powered leakage testing and SELV measurements using the quick test (QT) button, and can be used for testing fixed appliances.
The PAT150 includes the facility for mains powered leakage test. This test has the benefit that equipment under test will function during the test sequence.
Encased in rugged rubber armour and fitted with toughened Gorilla glass, the Megger PAT150 is incredibly durable. The PAT150R can be re-charged with NiMH batteries fitted.
Separated Extra Low Voltage (SELV) Supplies
SELV supplies should be tested to ensure the output voltage does not exceed maximum limits as defined in the international regulations for Extra Low voltage systems. The PAT150 permits up to 50 V ac measurement, with a PASS or fail indication for SELV.
FEATURES
Simple tick or cross, pass or fail indication plus measurement.
Battery powered with rechargeable options.
Includes 250 V insulation and leakage testing for safe IT testing and surge protected devices.
Testing portable and fixed electrical equipment.
10 mA and 30 mA portable RCD lead testing.
Adjustable PASS test limits and mains powered leakage testing.
Tough, rubber armoured with built-in front cover, hardened, scratch proof display window.
Environmental |
|||
Operating ambient |
20°C. | ||
Humidity |
Nominal humidity. | ||
Continuity |
|||
Test voltage |
Compliance Voltage: +4V dc –0% /+10 % (open circuit). | ||
Test current |
Bi-directional +200 mA -0% + 50 mA (into 2 Ω load). | ||
Continuity accuracy resistance | ± 5% ± 3 digits (0 to 19.99 Ω). | ||
Resistance resolution | 10 mΩ. | ||
Display range | 0.01 to 19.99 Ω. | ||
Test time |
User selectable from 2 sec to 20 sec or selected during test to 180sec. | ||
Insulation |
|||
Insulation test | 250 V dc –0 % /+25 % open circuit, 500 V dc –0 % /+25 % open circuit ≥ 500 V –0% dc across 0.5 MΩ load. |
||
Accuracy | ±3% ±10 digits (0 to 19.99 MΩ). | ||
Resolution | 0.01 MΩ. | ||
Display range | 0.10 MΩ to 99.99 MΩ. | ||
Test duration | User selectable from 2 sec to 20 sec or selected during test to 180 sec. | ||
Substitute Leakage Test | |||
Leakage current Accuracy | ± 5% ± 3 digits. | ||
Test frequency | Nominal mains frequency 50Hz. | ||
Test voltage | < 50V ac. | ||
Leakage Current Resolution | 0.01 mA. | ||
Display range | 0.10 to 19.99 mA. | ||
Test duration | User selectable from 2 sec to 5 seconds. Reading corrected to 230V ac. | ||
SELV Test | |||
Test voltage | 0 to 300 V ac. | ||
Accuracy | ± 3% ± 3 digits. | ||
Resolution | 0.1 V ac. | ||
Display range | 0.1 to 300 V ac. | ||
Mains Supply Test | |||
Frequency Measurement Range | 50 Hz. | ||
Test Voltage | 40 to 300 V AC. | ||
Accuracy | ±3% ± 3 digits. | ||
Resolution | 0.1 V AC. | ||
Display Range | 40 to 300V AC. | ||
General Specifications |
|||
Battery type | Eight AA LR6 cells 12 V dc (Alkaline cells) 9.6 V dc (NiMH cells). |
||
Battery life | Over 1000 full Class 1 tests using 3400 mAh Alkaline battery. | ||
Fixed PASS limits | Yes. | ||
IP rating | IP40 (with front cover closed). | ||
Dimentions | 203 mm (L) x 148 mm (W) x 78 mm (H). | ||
Weight | 1300g (45.8 oz). | ||
Megger PAT150R warranty | One year. |
COMPONENT |
DESCRIPTION | PART No. | ||
Adaptor | Extension lead adaptor 230 V, 13 A UK. | 1001-234 | ||
Case | Carry case PAT100 Series. | 1005-075 | ||
Strap | Carry strap. | 1005-076 | ||
Lead | UK mains plug test lead (BS1363 plug). | 6231-601 |