- settings_phone Telephone: 02890 830302
- mail belfast@cuthbertsonlaird.co.uk
- EUR €
- GBP £
Megger Torkel 950 Battery Load Tester
Includes: Megger Torkel 950, transport case Standard (GD-00954) and Mains cable Cable set, 2 x 3 m, 70 mm2 (GA-09550), Soft case for cables (GD-00360), TORKEL Viewer (CS-8010X), USB memory stick (HF-10 020).
Our pages are encrypted and protected from cyber-attack.
Payment Card Industry Data Security Standard (PCI DSS) Compliant.
TLS (SSL) - all data/information is secure from interception.
The TORKEL 950 is the fourth generation in the series of Megger’s trusted battery discharge test systems. Discharge testing is the only test method that provides a comprehensive insight into battery capacity, and is therefore an essential part of vigorous battery maintenance programmes.
Tests can be conducted at constant current, constant power, constant resistance or in accordance with a pre-selected load profile. Together with the cell voltage logger, BVM, now connected directly to the TORKEL 900, it becomes a complete stand-alone discharge test system.
The TORKEL is connected to the battery, the discharge current and the alarm levels (voltage, capacity, time) are set. After starting the discharge TORKEL keeps the current constant at the preset level. When the voltage drops to a level slightly above the final voltage, TORKEL issues an alarm. If the voltage drops so low that there is a risk for deep discharging the battery, TORKEL shuts down the test. All values are stored in TORKEL and can easily be transferred via an USB-stick to a PC for evaluation.
Testing can be carried out without disconnecting the battery from the equipment it serves. Via a DC clamp-on ammeter, TORKEL measures total battery current while regulating it at a constant level. Furthermore, the high discharge capacity of TORKEL gives the opportunity to shorten the test time. Discharging can take place at up to 220 A, and if higher current is needed, two or more TORKEL units or extra load units, TXL, can be linked together.
FEATURES
Discharge testing for full insight into battery capacity.
Enhanced safety features including spark free connection and emergency safety fuse.
Ability to test the battery without disconnecting it from the system.
High discharge capacity shortens the test time.
A complete stand-alone discharge test system.
TORKEL |
910 | 930 | 950 | ||||||
Current (max) | 110 A | 220 A | 220 A | ||||||
Voltage (max) | 300 V | 300 V | 500 V | ||||||
BVM functionality | |||||||||
Charging measurement | |||||||||
Full report functionality |
Current Measurement | |||
Display range | 0.0 to 2999.0 A. | ||
Basic inaccuracy | ± (0.5% of reading +0.1 A). | ||
Resolution | 0.1 A. | ||
Internal current measurement | 0 to 220 A. | ||
Input For Clamp-On Probe | |||
Range | 0 to 1000 mV DC. | ||
mV/A-ratio | 0.30 mV/A to 100.00 mV/A. | ||
Input impedance | >1 MΩ. | ||
Voltage Measurement | |||
Voltage | 0 to 500 V DC. | ||
Inaccuracy | ± (0.5% of reading +0.1 V DC). | ||
Resolution | 0.1 V. | ||
Sample rate | 10 Hz, Values are saved when change is >10 mV. | ||
Time Measurement | |||
Inaccuracy | ± 0.1% of reading ±1 digit. | ||
Load Section | |||
Battery voltage | 7.5 V to 300 V1) / 500 V2). | ||
Power | 15 kW (max). | ||
Load patterns | Constant current, constant power, constant resistance, current or power profile. | ||
Environment | |||
Operating Temperature | 0°C to +50°C (32°F to +122°F). | ||
Storage & transport | -40°C to +70°C (-40°F to +158°F). | ||
Shock/Vibration/Fall | Instrument only: ETSI EN 300 019-2-7 class 7M2 Instrument in transport case: ISTA 2A. |
||
Encapsulation class | IP20. | ||
CE-Marking | |||
LVD | IEC61010-1:2010 & IEC61010-2-030. | ||
EMC | IEC61326-1. | ||
General Specifications | |||
Mains voltage | 100 – 240 V AC, 50 / 60 Hz. | ||
Power consumption | 200 W (max). | ||
Power interruption | 40 ms (max). | ||
Protection | Thermal cut-outs, Automatic overload protection, Emergency stop button. | ||
Display | 7" LCD, Capacitive touch screen. | ||
Available languages | English, French, German, Spanish, Swedish. | ||
Dimensions | 519 x 315 x 375 mm, (20.5” x 12.4” x 14.7”). | ||
Weight | 19.5 kg (43.0 lbs) instrument 31.9 kg (70.3 lbs) incl. standard transport case 37 kg (82 lbs) incl. large transport case. |
||
Megger Torkel 950 warranty | One year. |
COMPONENT |
DESCRIPTION | PART No. | ||
Large Case | Transport case (Large) for TORKEL and standard cables. | GD-00955 | ||
TXL830 | Extra load unit incl. Cable set GA-09550, Control cables 2 x 2 m, Transport case. | BS-59093 | ||
TXL850 | Extra load unit incl. Cable set GA-09550, Control cables 2 x 2 m, Transport case. | BS-59095 | ||
TXL870 | Extra load unit incl. Cable set GA-00550, Control cables 2 x 2 m, Transport case. | BS-59097 | ||
TXL890 | Extra load unit incl. Cable set GA-00550, Control cables 2 x 2 m, Transport case. | BS-59099 | ||
Cable set | 2 x 3 m, 25 mm2, female / clamp. 110 A. 3.0 kg (6.6 lbs). | GA-00550 | ||
Extension cable | Extension for GA-00550, 2 x 3 m, 25 mm2, male / female. | GA-00552 | ||
Cable set, high rating | 2 x 3 m, 70 mm2, female / fork. 270 A. 5.0 kg (11 lbs). | GA-09550 | ||
Extension cable, high rating | Extension for GA-09550, 2 x 3 m, 70 mm2, male / female. | GA-09552 | ||
Sensing lead set | For measuring voltage at battery terminals, 2 x 5 m (16.4 ft). | GA-00210 | ||
DC clamp-on probe, 200 A | To measure current in external circuit. | XA-12992 | ||
DC clamp-on probe, 1000 A | To measure current in external circuit. | XA-12990 | ||
BVM, Single unit | Incl. Control cable black RJ45 0.5m (1.6 ft). | CJ-59090 | ||
BVM150 | System of 16 BVM units. | CJ-59092 | ||
BVM300 | System of 31 BVM units. | CJ-59093 | ||
BVM600 | System of 61 BVM units. | CJ-59096 |