- settings_phone Telephone: 02890 830302
- mail belfast@cuthbertsonlaird.co.uk
- EUR €
- GBP £
Fluke 712B RTD Temperature Calibrator
Includes: Fluke 712B RTD Calibrator, Protective Yellow Holster with Test Lead Storage, Instruction Sheet, Single 9V Alkaline Battery, Test Leads and Alligator Clips, NIST-Traceable Calibration Report and Data.
Our pages are encrypted and protected from cyber-attack.
Payment Card Industry Data Security Standard (PCI DSS) Compliant.
TLS (SSL) - all data/information is secure from interception.
For the temperature calibration professional that wants a highly accurate, easy-to-use, single function temperature calibrator the Fluke 712B is the ideal test tool. The 712B combines the portability of a Fluke multimeter with the capabilities of a Fluke documenting process calibrator to give this device portability and several functions that are ideal for RTD simulation and measurements.
FEATURESThe 712B can measure and simulate (13) different RTD types and resistance.
Measure 4 to 20 mA signals while simultaneously sourcing a temperature signal.
Hanging tool designed in and included with every unit.
Configurable 0% and 100% source settings for quick 25% linearity checks.
Linear ramp and 25% step auto ramp based on 0% and 100% settings.
Dual inputs and backlit display for easy interpretation of measurements.
Power down settings remembered at power up for easy restart of tests.
1-year and 2-year specifications and traceable certificate of calibration.
Max voltage applied between any terminal and earth ground or between any two terminals | 30 V. | ||
Operating temperature | -10 °C to 50 °C. | ||
Storage temperature | - 30 °C to 60 °C. | ||
Relative humidity (% RH operating without condensation) | Non condensing 90% (10 °C to 30 °C) 75% (30 °C to 40 °C) 45% (40 °C to 50 °C) (Without condensation). |
||
Drop test requirements | 1 meter. | ||
IP Rating | IEC 60529: IP52. | ||
Electromagnetic environment | IEC 61326-1, Portable. | ||
Safety | IEC 61010-1, Max 30 V to earth, Pollution Degree 2. | ||
DC mA Measurement | |||
Resolution | 0-24 mA. | ||
Range | 0.001 mA. | ||
Accuracy (% of reading + counts) | 0.010% + 2 μA. | ||
Temperature coefficient | ± (0.002% of reading + 0.002% of range) /°C ( <18 °C or >28 °C). | ||
Ohms Measurement | |||
Ohms range | Accuracy (% of reading +counts) | ||
0.00 Ω to 400.00 Ω | 0.015% + 0.05 Ω. | ||
Note: Read accuracy is based on 4-wire input. For 3-wire ohm measurements, assuming all three leads are matched, add 0.05 Ω (0.00 Ω~400.00 Ω), 0.2 Ω (400.0 Ω~4000.0 Ω) to the specifications. | |||
Temperature coefficient | ± (0.002% of reading + 0.002% of range) /°C ( <18 °C or >28 °C). | ||
Ohms Source | |||
Ohms range | 1.0 Ω to 400.0 Ω 1.00 Ω to 400.00 Ω 400.0 Ω to 1500.0 Ω 1500.0 Ω to 4000.0 Ω. |
||
Excitation current from measurement device | 0.1 mA to 0.5 mA 0.5 mA to 3 mA 0.05 mA to 0.8 mA 0.05 mA to 0.4 mA |
||
Accuracy (% of reading + counts) | 0.015% + 0.1 Ω 0.015% + 0.05 Ω 0.015% + 0.5 Ω 0.015% + 0.5 Ω. |
||
Temperature coefficient | ± (0.002% of reading + 0.002% of range) /°C ( <18 °C or >28 °C). Supports pulsed transmitters and PLCs with pulse times as short as 5 ms. | ||
Power supply | 4 AA NEDA 1.5A IEC LR6 batteries. | ||
Dimensions (H x W x L) | 52.5 mm x 84 mm x 188.5 mm. | ||
Weight | 515 g. | ||
Fluke 712B warranty | 3 years. |
COMPONENT |
DESCRIPTION | PART No. | ||
80PK-1 | Bead probe (type K). | 750422 | ||
80PK-8 | Pipe clamp temperature probe (type K). | 200360 | ||
C25 | Soft meter case. | 681114 |