Fluke 1630-2 FC Earth Ground Clamp
  • Fluke 1630-2 FC Earth Ground Clamp
  • Fluke 1630-2 FC Earth Ground Clamp
  • Fluke 1630-2 FC Earth Ground Clamp

Fluke 1630-2 FC Earth Ground Clamp

Fluke authorised distributor and calibration house.

Stakeless earth ground loop and ac leakage current clamp for fast, safe indoor/outdoor earth ground resistance and ac leakage current tests.

Quantity
  HTTPS Secure

Our pages are encrypted and protected from cyber-attack.

  Compliant

Payment Card Industry Data Security Standard (PCI DSS) Compliant.

  Protected

TLS (SSL) - all data/information is secure from interception.

The Fluke 1630-2 FC Stakeless Earth Ground Clamp is the kind of high-quality, rugged tool you expect from Fluke. Heavy-duty clamp jaw stays in alignment and in calibration even in every day, on-the-job industrial environments.

Test the grounding components of equipment in hard-to-reach spaces, including areas that are indoors or fully paved and do not permit driving auxiliary test stakes. Stay on line—identify ground loop resistance without the need to disconnect then reconnect the earth electrode from the system.

The 1630-2 FC clamp measures earth ground loop resistances for multi-grounded systems using the dual-clamp jaw. This test technique eliminates the dangerous and time-consuming activity of disconnecting parallel grounds, as well as the process of finding suitable locations for auxiliary test stakes. You can also perform ground tests in places that were previously difficult: inside buildings, on power pylons or anywhere you don’t have access to soil to place auxiliary test stakes.

Fluke 1630-2 FC Specifications:

  • Conductor size: 40 mm (1.57 in) approximately.
  • Maximum voltage to earth ground: 1000 V.
  • Frequency range: 40 Hz to 1 kHz.
  • Ingress protection: IEC/EN 60529: IP30 with jaw closed.
  • Operating temperature: -10 °C to +50 °C (14 °F to +122 °F).
  • Resistance ranges: 0.025 to 0.249Ω, 0.250 to 0.999Ω, 1.000 to 9.999Ω, 10.00 to 49.99Ω, 50.00 to 99.99Ω, 100.0 to 199.9Ω, 200.0 to 399.9Ω, 400 to 599Ω, 600 to 1500Ω.
  • Overload indication: OL.
  • LCD Digital reading: 9999 counts.
  • Data logging capacity: Minimum of 32,760 measurements.
  • Data logging interval: 1 second to 59 minutes and 59 seconds.
  • Battery type: 4 x 1.5 V AA alkaline IEC/EN LR6.
  • Battery life: More than 15 hours (backlight and RF mode turned off).
  • Dimensions (L x W x H): 283 mm x 105 mm x 48 mm (11.1 in x 4.1 in x 1.9 in).
  • Weight: 880g (31 oz).
  • Fluke 1630-2FC warranty: One year.

Includes: Fluke 1630-2 Earth Ground clamp, Hard case, Loop resistance standard, 4 AA batteries, Safety information guide, Quick reference guide.